Broadband Current Probe, EMC/EMI Antennas
Request a quote Antenna Catalog
9710 Cozycroft Ave. Chatsworth CA, 91311 · Call us at (818) 998 0223 to speak with a representative
EMI/EMC Antennas
 
EMI/EMC Antenna Catalog

  » Accessories
  » Antenna Kits
  » Biconicals
  » Bilogicals
  » Current Probes
  » Dipoles
  » H-Field Rods
  » Horns
  » Log Periodics
  » Loops
  » Monopoles
  » Preamplifiers
 

BCP-519
Broadband Current Probe
100 Hz - 100 MHz

This probe can be used to measure small RF currents in the basic configuration and pulse currents with wide ranging magnitudes with the supplied external power absorbing terminator.

larger image

Frequency Range: 100 Hz - 100 MHz
Transfer Impedance (dBW) -40 to 17
Max Cont. Current (Amps) 200
Connector: N-Type, Female
Physical Dimensions
Aperture: 2.6" (67 mm)
Diameter: 5.5" (142 mm)
Weight: 6.0 lb.'s (2.72 kg)

Features
  • Measures currents on 50 Hz, 60 Hz and 400 Hz powerlines
  • Ideally suited to measuring currents on large cables.
  • Individually Calibrated (Transfer Impedance calibration included)
  • High Current Capability
  • Split Type Clamp-on Design
  • External Power Absorbing Terminator

Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on current probes. The BCP-519 Current Probe is designed to permit field intensity meters, spectrum analyzers, and other 50 ohm impedance instruments to measure quantitative magnitudes of current. Measurements can be made on single and multi-conductor cables, ground and bonding straps, shielded conduits and on coaxial cables.

The BCP-519 has a usable frequency range of 100 Hz to 100 MHz with a transfer impedance of 0.005 ohms from 10 kHz to 100 MHz. Primary power currents of 200 amperes DC to 60 Hz, 70 amperes 400 Hz and 60 amperes CW and 5,000 amperes pulse will not alter the transfer impedance. This probe can be used to measure small RF currents in the basic configuration and pulse currents with wide ranging magnitudes with the supplied external power absorbing terminator.

Recommended Accessories

  • CPF-530 (Current Probe Fixture)
  • SAC-213 (3 meter N/N Cable, RG-58A/U)

More Information

 

To download Adobe's free Acrobat Reader software,
click the Get Acrobat Reader button below.

 



Quality Statement | Policies | Warranty | Email

A.H. Systems, inc.
9710 Cozycroft Ave. • Chatsworth, CA 91311
phone: (818) 998-0223 • fax: (818) 998-6892