Broadband Current Probes 20 Hz - 1 GHz

These Current Probes are devices used in a wide variety of industrial and scientific applications, and designed to be used in the process of generating and measuring high levels of RF current. Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on broadband current probes. These EMC Current Probes are designed to permit field intensity meters, spectrum analyzers, and other 50 ohm impedance instruments to measure quantitative magnitudes of current. Measurements can be made on single and multi-conductor cables, ground and bonding straps, shielded conduits and on coaxial cables.


View a comparison of the specifications for our broadband current probes.

Low frequency current probe

BCP-610

20 Hz - 20 MHz

This current probe measures currents on 50 Hz, 60 Hz and 400 Hz powerlines andhas a usable frequency range of 20 Hz - 20 MHz.

Monitoring Current probe

BCP-611

10 KHz - 150 MHz

This probe is capable of measuring pulse currents up to 100 amperes with wide operating frequency of 10 KHz - 150 MHz.

Large clamp on current probe

BCP-614

10 KHz - 300 MHz

This probe is capable of measuring pulse currents up to 100 amperes with wide operating frequency of 10 KHz - 300 MHz.

Standard Current probe

BCP-615

10 KHz - 500 MHz

This probe is capable of measuring pulse currents up to 100 amperes with wide operating frequency of 10 KHz - 500 MHz.

Standard Current probe

BCP-616

10 KHz - 150 MHz

This probe is capable of measuring pulse currents up to 100 amperes with wide operating frequency of 10 KHz - 150 MHz.

Large aperature Current probe

BCP-618

100 KHz - 500 MHz

This probe can be used to measure small RF currents in the basic configuration and pulse currents with wide ranging magnitudes.

Current probe for measuring pulse currents

BCP-619

100 Hz - 100 MHz

This probe can be used to measure small RF currents in the basic configuration and pulse currents with wide ranging magnitudes.

MIL-STD-461 monitoring current probe

BCP-620

10 KHz - 500 MHz

MIL-STD 461 CS114 Current Probe

Injection Current Probe

ICP-621

10 KHz - 100 MHz

This injection current probe can be used as injection source as well as a sensitive monitoring probe.

500 MHz Injection Probe

ICP-622

1 MHz - 500 MHz

This injection current probe is used to couple large RF currents into signal and power circuits to meet specific testing requirements. MIL-STD 461.

High Frequency Injection Probe

ICP-623

5 MHz - 1 GHz

For high frequency bulk injection testing.

Current Probe Fixture

CPF-630

20 Hz - 500 MHz

Most Bulk Current Injection Test Procedures require the use of current probe fixtures.

High Frequency Fixture

CPF-631

400 MHz - 1.5 GHz

Most Bulk Current Injection Test Procedures require the use of current probe fixtures.